Understanding your boiler
Vaillant boiler fault codes
19 Apr 2024 • 4 minutes
If your Vaillant boiler is displaying a code beginning with the letter F, then it is signalling that the appliance is experiencing a fault. To help fix your Vaillant boiler fault code, have a look below
Jump to:
F.49
F.52
F.53
F.54
F.56
F.57
F.61
F.62
F.63
F.64
F.65
F.67
F.68
F.70
F.71
F.72
F.73
F.74
F.75
F.76
F.77
F.78
F.83
F.84
F.85
F.92
F.93
Short circuit on the eBUS, eBUS overload or two power supplies with different polarities on the eBUS.
Mass flow sensor not connected/disconnected, plug not connected or incorrectly connected or an issue with its operation.
Mass flow sensor faulty, filter below venturi filter cap wet or blocked, gas flow pressure too low.
No or too little gas supply pressure, gas valve closed.
Gas valve defective, cable harness to gas valve defective.
Ignition electrode is highly corroded.
Defective electronics
Supply or return NTC short circuited, electronics defective.
Electronics overheating due to external influences
Implausible flame signal, electronics defective.
This could be caused by:
Spare part case: Display and PCB replaced at same time and DSN not set, wrong or missing output range coding resistor.
Flow temperature sensor signalling constant value:
Flow/return NTC temperature difference too great → flow and/or return temperature sensor defective.
Cable to water pressure sensor has short-circuited at 5V/24 V or internal fault in water pressure sensor.
Cable or cable connections for safety fuse in primary heat exchanger or primary heat exchanger defective.
No response from flue non-return flap or condensate pump defective.
UK link box is connected, but the hot water NTC is not bridged.
Flow and/or return temperature sensors have been fitted to the same pipe/wrong pipe.
The coding resistor on the PCB does not match the entered gas family. Check the resistor, repeat the gas family check and enter the correct gas family.
Combustion quality outside the permitted range: Wrong gas restrictor, recirculation, wrong gas family, internal pressure measuring point in venturi blocked (do not use lubricant on O-ring in venturi.). Gas family check prematurely terminated.
No communication with PCB.
Experiencing problems with your Vaillant boiler? Our expert repairs team are on hand to diagnose the issue and will aim to get things working again in no time.
Alternatively, if you’re looking for a new boiler, we’re working together with BOXT, one of the largest boiler installation companies in the UK, to help you find the best boiler for your home.
BOXT makes choosing the perfect new boiler for your home easy with a fixed price quote on your screen in just 90 seconds.
Our help & advice articles cover Plumbing, Home heating, Electrical, Energy-saving and Home maintenance.